SJ RV 150⚡ Permanent Magnet VFD

Power: 150 HPDual Voltage (50/60 Hz Global Ready)
✓ ISO 9001:2015 Certified
✓ CE Standard Design
✓ IS 5456 Performance Rating
High Pressure Variable Speed SJ Screw Air Compressor VFD/VSD•Model Code: SJ RV 150
150 HP 10 Bar SJ VFD Variable Speed Screw Air Compressor
Explore the Sarv Jagat SJ RV150 150 HP 10 Bar VFD Screw Air Compressor, delivering 600 CFM (16.99 m³/min) for demanding industrial compressed air applications.
Motor Power150 HP110 kW Electrical
Working Pressure10 Bar145 PSI Rating
Free Air Delivery600 CFM16.99 m³/min
Core Engineering Highlights:
Permanent Magnet Synchronous Motor (IE4 super-premium efficiency rating)
Advanced vector inverter frequency control saving up to 35% on electrical costs
Precision asymmetric twin-screw rotor profile with SKF heavy-duty bearings
Smart MAM-880 micro-computer controller with pressure & temperature protection
Soft-start zero inrush current design extending motor and mechanical life
Factory Hotline: +91-9157487233Worldwide Sea-Worthy Packaging
Verified Technical Data Sheet
ENGINEERING SPECIFICATIONS — SJ RV 150
| Specification Parameter | Certified Engineering Rating |
|---|---|
| Motor Power | 150 HP / 110 kW |
| Working Pressure (Discharge) | 10 Bar / 145 PSI / 1 MPa |
| Free Air Delivery (FAD Capacity) | 600 CFM / 16.99 m³/mi |
| Drive Type | Variable Speed VFD (Permanent Magnet) |
| Cooling System | Oversized Vacuum-Brazed Aluminum Heat Exchanger |
| Micro-Controller PLC | MAM-880 Intelligent Micro-Computer with RS-485 Modbus |
| Electrical Grid Compatibility | 415V ±10% / 3-Phase / 50 Hz (Dual Voltage 50/60 Hz Available) |
| Operating Sound Level | 74 ± 2 dB(A) Acoustic Enclosure |
| Unit Dimensions (L × W × H) | 2200 x 1400 x 1850 mm |
| Approx. Net Weight | 3450 kg |
| Cooling Method | High Efficiency Air Cooled |
| Voltage & Frequency | 415V ±10% / 3-Phase / 50 Hz |
| Stage | Single Stage |
| Type | Variable Speed (VFD) |
| Technology | Oil Injected Rotary Screw |
| Drive | Direct Driven |
Technical Documentation & Plant Application Guide
PRODUCT OVERVIEW & ENGINEERING GUIDE
Authored by Sarv Jagat Corporation Engineering Team • Official Product Whitepaper
150 HP 10 Bar SJ VFD Variable Speed Screw Air Compressor – SJ RV150
The SJ RV150 is a 150 HP (110 kW) industrial variable-speed rotary screw air compressor designed for manufacturing facilities and industrial operations requiring substantial compressed air capacity at 10 bar pressure.
With a specified airflow of 600 CFM (16.99 m³/min) at 10 bar, the SJ RV150 is intended for high-capacity compressed air installations supporting multiple production departments, automated machinery, large CNC machining clusters and other demanding industrial applications.
The compressor combines single-stage rotary screw compression technology with Variable Frequency Drive (VFD) operation. The VFD adjusts motor speed according to compressed air demand within the compressor's designed operating range. This allows the compressor's output to respond to changing consumption instead of relying exclusively on fixed-speed operation.
At large industrial facilities, compressed air demand can change as production lines start, stop, operate at different loads or move between production cycles. Selecting an appropriate compressor control arrangement is therefore important for managing pressure and matching air generation with actual consumption.
The SJ RV150 is designed for applications where the required operating pressure is 10 bar and the specified airflow requirement is within its rated capacity.
KEY PRODUCT SPECIFICATIONS
• Model: SJ RV150
• Compressor Type: Industrial Rotary Screw Air Compressor
• Motor Power: 150 HP / 110 kW
• Operating Pressure: 10 Bar
• Pressure Equivalent: 145 PSI / 1 MPa
• Rated Air Flow: 600 CFM
• Metric Air Flow: 16.99 m³/min
• Compression Stage: Single Stage
• Operating Technology: Variable Speed
• Drive Technology: Variable Frequency Drive (VFD)
WHY CHOOSE THIS CAPACITY?
A 150 HP compressor is generally considered when an industrial facility has a substantial combined compressed air requirement across several machines, production lines or departments.
The SJ RV150 provides a specified airflow of 600 CFM at 10 bar. Its capacity should be evaluated against the actual compressed air consumption of the plant, including simultaneous machine operation, peak demand and future expansion.
1. HIGH-CAPACITY AIR SUPPLY
With a rated airflow of 600 CFM (16.99 m³/min) at 10 bar, the SJ RV150 can be evaluated for large industrial installations where smaller compressors may not provide the required combined airflow.
It may be considered for:
• Large CNC and VMC machining clusters.
• Automotive manufacturing facilities.
• High-capacity packaging and bottling operations.
• Industrial automation and pneumatic production systems.
• Large engineering and fabrication plants.
• Centralized compressed air networks.
2. VARIABLE AIR DEMAND MANAGEMENT
Industrial compressed air consumption is rarely constant throughout the entire production day.
For example:
• Some production lines may operate continuously.
• Other machines may operate intermittently.
• Pneumatic equipment may consume air in short production cycles.
• Different departments may operate at different production rates.
• Shift changes can create variations in total air consumption.
The VFD arrangement allows motor speed to be adjusted according to the compressor's control demand, within the designed operating range.
This makes variable-speed technology relevant to installations with changing compressed air consumption.
3. SUITABLE FOR CENTRALIZED COMPRESSED AIR SYSTEMS
Large manufacturing facilities often use a centralized compressor room to supply multiple production areas through a common compressed air distribution network.
The SJ RV150 can be evaluated as a primary compressed air source where the calculated plant demand is compatible with its 600 CFM rating at 10 bar.
The system design should consider:
• Total connected compressed air demand.
• Simultaneous operating airflow.
• Peak and average consumption.
• Required pressure at the point of use.
• Air receiver capacity.
• Pipeline diameter and pressure losses.
• Air leakage.
• Required compressed air quality.
• Future production expansion.
A compressor should not be selected only by adding the nominal consumption of every connected machine. Actual simultaneous demand and operating patterns should be assessed.
4. 10 BAR INDUSTRIAL PRESSURE REQUIREMENT
The SJ RV150 is specified for a 10 bar operating pressure configuration.
This pressure level should be selected when the connected machinery and production processes genuinely require it.
Before choosing a 10 bar compressor, evaluate:
• Minimum pressure required by production machinery.
• Pressure losses across filters, dryers and pipelines.
• Pressure requirement at the most distant point of use.
• Pressure fluctuations during peak consumption.
• Possibility of reducing system pressure through better distribution design.
Operating at a higher pressure than necessary can increase electricity consumption. Therefore, the system should be designed around the minimum pressure that reliably satisfies the production requirement.
ADVANCED ROTARY SCREW COMPRESSION TECHNOLOGY
The SJ RV150 uses single-stage rotary screw compression technology for industrial compressed air generation.
A rotary screw compressor uses two intermeshing helical rotors inside a compression element. Air enters through the intake side, becomes trapped between the rotor profiles and casing, and is compressed as it moves towards the discharge side.
This continuous compression process is suitable for industrial installations requiring a substantial compressed air supply.
PRINCIPAL COMPRESSION PROCESS
1. AIR INTAKE
Ambient air enters through the compressor's air intake arrangement.
An intake filtration system helps reduce the entry of dust and airborne particles into the compression system.
The intake filter must be maintained according to the operating environment and service schedule. Dust accumulation can restrict airflow and increase the pressure drop across the filter.
2. ROTARY SCREW COMPRESSION
The compression element uses two rotating screw rotors to reduce the volume of trapped air and increase its pressure.
The compressor's single-stage compression arrangement is designed to deliver compressed air according to the selected operating pressure configuration.
3. LUBRICATION AND INTERNAL COOLING
For an oil-injected rotary screw configuration, lubricating oil performs several functions within the compression process.
These functions generally include:
• Lubrication of moving components.
• Sealing between rotor clearances.
• Absorption and removal of heat generated during compression.
• Supporting the operating conditions of the compression element.
The exact oil circuit and component arrangement depend on the supplied compressor configuration.
4. AIR-OIL SEPARATION
In an oil-injected screw compressor, compressed air leaving the compression element contains oil that must be separated before the air is delivered to the downstream system.
An air-oil separation arrangement reduces oil carryover in the compressed air stream.
The air-oil separator element requires inspection and replacement according to the manufacturer's maintenance schedule and operating conditions.
5. COMPRESSED AIR DISCHARGE
After the separation and cooling stages included in the supplied configuration, compressed air is discharged towards the downstream compressed air installation.
Depending on the system design, downstream equipment may include:
• Air receiver tank.
• Moisture separator.
• Refrigerated or desiccant air dryer.
• Compressed air filters.
• Distribution piping.
The required treatment arrangement depends on the application and specified compressed air quality.
VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY
The SJ RV150 uses Variable Frequency Drive technology to regulate motor speed according to compressed air demand within its designed operating range.
This is particularly relevant for large industrial installations where compressed air consumption changes throughout the production cycle.
Unlike a conventional fixed-speed arrangement, where the motor operates at a substantially fixed speed during loaded operation, a VFD compressor can vary motor speed by adjusting the electrical frequency supplied to the motor.
HOW VFD CONTROL WORKS
1. PRESSURE MONITORING
The compressor control arrangement monitors system pressure through its configured pressure feedback system.
2. DEMAND RESPONSE
When compressed air demand increases, system pressure can decrease. The control system can increase motor speed within the permitted operating range to respond to the increased demand.
3. SPEED ADJUSTMENT
When compressed air consumption decreases, the control system can reduce motor speed within the designed operating limits.
4. AIRFLOW REGULATION
Changing motor speed changes compressor output. This allows air generation to respond to variations in system demand.
5. PRESSURE CONTROL
The VFD and controller work together to regulate compressor operation according to the configured pressure settings and control parameters.
OPERATIONAL RELEVANCE IN LARGE INDUSTRIAL PLANTS
Consider a manufacturing facility operating several production departments.
During one production period, multiple CNC machines, pneumatic fixtures and automated assembly lines may operate simultaneously. During another period, some machines may stop while others continue running.
The total compressed air demand therefore changes.
A variable-speed compressor can adjust motor speed to respond to these changes within its designed operating range.
POTENTIAL OPERATIONAL BENEFITS
• Variable Output: Compressor airflow can be adjusted according to demand within the designed operating range.
• Demand Matching: Helps match air generation with changing plant consumption.
• Pressure Regulation: Supports pressure regulation through the configured VFD and controller arrangement.
• Reduced Load-Unload Cycling: Variable-speed operation can reduce reliance on conventional load-unload cycling under suitable operating conditions.
• Partial-Load Operation: Can reduce unnecessary full-speed operation when plant demand is below the compressor's available capacity.
• Centralized System Integration: Can be evaluated for compressed air networks with changing demand.
VFD ENERGY CONSUMPTION CONSIDERATIONS
A VFD does not guarantee a fixed percentage of electricity savings.
Actual energy performance depends on:
• Daily compressed air demand profile.
• Average operating load.
• Required system pressure.
• Compressor operating range.
• Air leakage throughout the distribution network.
• Number of operating compressors.
• Control strategy.
• Operating hours.
• Maintenance condition.
The greatest potential for energy reduction generally exists where compressed air demand varies sufficiently and the compressor can operate efficiently across the required range.
If the plant operates continuously near full compressor capacity, the energy advantage over a correctly selected fixed-speed compressor may be limited.
For this reason, a demand assessment and comparison of specific power consumption under actual operating conditions are recommended before making an energy-saving estimate.
PRESSURE-WISE AIRFLOW CONFIGURATIONS
The official SJ specification sheet lists different airflow capacities for the SJ RV150 at different pressure configurations.
• 8 Bar: 717 CFM / 20.31 m³/min
• 10 Bar: 600 CFM / 16.99 m³/min
• 13 Bar: 516 CFM / 14.61 m³/min
For this product page, the applicable configuration is:
SJ RV150 – 150 HP – 10 Bar – 600 CFM – 16.99 m³/min.
The airflow figures for 8 bar and 13 bar must not be used as the rated airflow for the 10 bar configuration.
PREMIUM INDUSTRIAL COMPONENTS
A 150 HP industrial screw compressor requires appropriately selected mechanical, electrical and cooling components to support its intended operating conditions.
The following are important functional systems to consider in the SJ RV150 configuration. Exact component brands, specifications and supplied arrangements should be confirmed in the approved technical quotation.
1. ROTARY SCREW AIR END
The air end is the principal compression component of a rotary screw compressor.
Its rotor geometry, clearances, lubrication requirements and operating speed influence compressor performance.
For the SJ RV150, the air end must be selected to support the specified operating pressure and airflow configuration.
2. INDUSTRIAL ELECTRIC MOTOR
The motor supplies the mechanical power required to drive the compression element.
The SJ RV150 has a specified motor power rating of 150 HP (110 kW).
Motor selection should account for:
• Rated power.
• Operating speed.
• Electrical supply.
• Insulation and enclosure requirements.
• VFD compatibility.
• Cooling requirements.
• Permitted operating frequency range.
The exact motor make, efficiency class, protection rating and insulation details should be confirmed from the supplied motor documentation.
3. VARIABLE FREQUENCY DRIVE
The VFD regulates the electrical frequency supplied to the motor and controls motor speed according to the configured compressor control strategy.
Correct VFD selection is important for a 150 HP motor.
The drive must be suitable for the motor rating, operating conditions, electrical supply and compressor operating range.
4. AIR INTAKE FILTER
The intake filter reduces the entry of dust and airborne particles into the compressor.
Its condition affects intake airflow and contributes to protection of the compression system.
Inspection frequency should be adjusted according to the dust concentration and operating environment.
5. OIL FILTER
The oil filter removes contaminants from the lubricating oil circuit.
Maintaining suitable oil filtration helps protect the lubrication system and compression element.
Replacement should follow the manufacturer's maintenance schedule and the actual operating conditions.
6. AIR-OIL SEPARATOR ELEMENT
The separator element reduces oil carryover from compressed air in an oil-injected screw compressor.
Its condition influences separation performance and pressure drop.
The element should be inspected and replaced according to the manufacturer's specified service interval and operating conditions.
7. COOLING SYSTEM
The compressor cooling arrangement helps control operating temperatures.
Depending on the supplied configuration, the cooling system may include an oil cooler, compressed air aftercooler and cooling fan.
Adequate ventilation and regular cleaning are important for maintaining suitable operating conditions.
8. ELECTRICAL CONTROL PANEL
The electrical control system coordinates compressor operation and available protection functions.
It may include the VFD, controller, electrical protection devices and associated control components according to the supplied configuration.
Correct installation, earthing, protection coordination and parameter configuration are essential for reliable operation.
RELIABLE INDUSTRIAL PERFORMANCE
The SJ RV150 is intended for industrial applications where a large compressed air supply is required at a specified pressure of 10 bar.
Its 150 HP motor rating, single-stage rotary screw compression arrangement and VFD operating technology provide a configuration for evaluating high-capacity compressed air generation in manufacturing and process environments.
For reliable system operation, compressor selection should be supported by an assessment of actual airflow demand, pressure requirements, air treatment, electrical infrastructure and installation conditions.
IMPORTANT INSTALLATION CONSIDERATIONS
Before installing the SJ RV150, evaluate:
• Electrical supply capacity for a 150 HP / 110 kW motor and its VFD arrangement.
• Suitable cable sizing, protection and earthing.
• Compressor room ventilation and heat removal.
• Required service and maintenance clearance.
• Foundation and floor-loading suitability.
• Air receiver and downstream treatment requirements.
• Compressed air pipeline sizing.
• Pressure drop across the distribution network.
• Ambient temperature and site conditions.
• Condensate collection and disposal arrangements.
The compressor should be installed and commissioned according to the approved manufacturer's instructions and applicable electrical and safety requirements.
APPLICATION-BASED CAPACITY SELECTION
The SJ RV150 should be selected when the calculated compressed air requirement is compatible with its specified capacity of 600 CFM at 10 bar.
For plants with variable demand, the VFD arrangement can be evaluated against the actual demand profile.
For plants with consistently high demand, the selection should also consider the compressor's operating range, full-load requirements and the possible use of multiple compressors.
A correctly engineered compressed air system should provide the required pressure and airflow at the point of use without unnecessary pressure losses or excessive operating pressure.
HEAVY DUTY COOLING SYSTEM
The SJ RV150 is a 150 HP (110 kW) industrial screw air compressor intended for high-capacity compressed air applications. Effective heat management is important for maintaining suitable operating conditions across the compression, lubrication and electrical systems.
The cooling arrangement helps remove heat generated during compressor operation. Depending on the supplied configuration, the system may include the following functional components:
• Oil Cooler: Helps regulate lubricating oil temperature in an oil-injected compressor arrangement.
• Compressed Air Aftercooler: Reduces compressed air temperature before downstream treatment, where included.
• Cooling Fan: Supports heat removal from the compressor package.
• Ventilation System: Helps maintain airflow through the compressor enclosure.
• Temperature Monitoring: Supports monitoring of selected operating temperatures, subject to controller configuration.
COOLING AND INSTALLATION REQUIREMENTS
For a 150 HP compressor, compressor-room ventilation and heat removal should be considered during installation planning.
Important considerations include:
• Adequate ventilation in the compressor room.
• Sufficient clearance around cooling air intake and discharge openings.
• Prevention of hot cooling-air recirculation.
• Regular cleaning of cooling surfaces and ventilation openings.
• Suitable ambient temperature for the compressor package.
• Provision for removal or ducting of hot cooling air where necessary.
• Accessibility for inspection and scheduled maintenance.
Poor ventilation, blocked cooling surfaces or excessive ambient temperature can adversely affect compressor operating conditions. The final cooling arrangement and permissible operating limits should be confirmed from the supplied technical documentation.
INTELLIGENT ELECTRICAL & SAFETY FEATURES
The SJ RV150 uses Variable Frequency Drive technology to regulate motor speed according to compressed air demand within its designed operating range.
The electrical control system coordinates motor operation, variable-speed regulation and available monitoring and protection functions.
Depending on the supplied VFD, controller and electrical panel configuration, functional provisions may include:
• Variable Frequency Drive: Adjusts the electrical frequency supplied to the motor to regulate operating speed.
• Motor Protection: Provides protection against specified motor operating faults.
• Overload Protection: Helps protect the motor and electrical system against excessive loading.
• Phase Protection: Provides phase-related electrical protection where included in the panel.
• Temperature Monitoring: Monitors selected compressor temperatures where supported by the controller.
• Pressure Monitoring: Provides pressure feedback for compressor control according to the supplied arrangement.
• Emergency Stop: Provides an emergency stopping function according to the electrical configuration.
• Operating Status Display: Displays available operating information and system conditions.
• Fault Indication: Indicates detected faults according to controller functionality.
ELECTRICAL INSTALLATION CONSIDERATIONS
The 150 HP / 110 kW motor and VFD arrangement require appropriate electrical infrastructure.
Before commissioning, verify:
• Electrical supply compatibility.
• VFD rating and motor compatibility.
• Cable sizing and current-carrying capacity.
• Correct earthing and electrical protection.
• Suitable ventilation for the electrical panel and VFD.
• Correct drive parameter configuration.
• Protection coordination with the plant electrical system.
Electrical installation and commissioning should follow the manufacturer's documentation and applicable electrical standards.
STANDARD FEATURES
The following describes the principal functional systems associated with the SJ RV150 product configuration. Exact component brands, ratings and included equipment should be confirmed in the approved quotation.
• 150 HP industrial variable-speed rotary screw air compressor.
• 110 kW motor power rating.
• 10 bar maximum operating pressure rating.
• Rated airflow of 600 CFM (16.99 m³/min) at 10 bar.
• Single-stage rotary screw compression arrangement.
• Variable Frequency Drive (VFD) operating technology.
• Variable motor speed within the designed operating range.
• Air intake filtration system.
• Lubrication system for oil-injected compressor configuration.
• Oil filtration system.
• Air-oil separation system for oil-injected configuration.
• Compressor cooling arrangement.
• Electrical control and protection system.
• Compressor controller according to supplied configuration.
• Pressure monitoring and variable-speed regulation according to the supplied control arrangement.
• Industrial enclosure, where included in the supplied configuration.
OPTIONAL FEATURES
The SJ RV150 can be integrated with additional compressed air storage, treatment and distribution equipment according to the requirements of the industrial installation.
The following equipment should be considered optional unless specifically included in the approved quotation.
• Refrigerated Air Dryer: Reduces moisture content for general-purpose industrial compressed air.
• Desiccant Air Dryer: Provides lower pressure dew point air where required by the process.
• Air Receiver Tank: Stores compressed air and helps manage short-duration demand fluctuations.
• Moisture Separator: Removes bulk liquid moisture from compressed air.
• Pre-Filter: Removes particulate contamination and liquid aerosols according to its filtration rating.
• After-Filter: Provides additional downstream filtration.
• Micro Filter: Supports finer aerosol filtration requirements.
• Activated Carbon Filter: Helps reduce oil vapour and odour, subject to filter design and operating conditions.
• Automatic Drain Valve: Removes accumulated condensate from selected system components.
• Aluminium Compressed Air Piping: Distributes compressed air across the factory.
• Oil-Water Separator: Treats oil-contaminated condensate before disposal, subject to applicable environmental requirements.
• Airflow Meter: Measures compressed air consumption across the distribution network.
• Dew Point Monitor: Monitors moisture performance downstream of the air dryer.
AIR TREATMENT SELECTION FOR 600 CFM
For the SJ RV150 10 bar configuration, downstream equipment should be selected for the actual operating airflow of 600 CFM at 10 bar.
Important selection parameters include:
• Rated airflow capacity of the dryer and filters.
• Operating pressure and permissible pressure drop.
• Compressor-room ambient temperature.
• Dryer inlet compressed air temperature.
• Required pressure dew point.
• Required filtration grade.
• Condensate load and drain capacity.
• Future production expansion requirements.
An undersized dryer or filter can create excessive pressure drop and restrict usable airflow available to production equipment.
For large centralized installations, the air treatment system should be designed around actual air quality requirements and operating conditions rather than selected only according to compressor horsepower.
TECHNICAL SPECIFICATIONS
Model Number: SJ RV150
Product Type: Industrial Rotary Screw Air Compressor
Compressor Technology: Rotary Screw
Operating Technology: Variable Speed
Drive Technology: Variable Frequency Drive (VFD) / Variable Speed Drive (VSD)
Compression Stage: Single Stage
Motor Power: 150 HP
Motor Power: 110 kW
Maximum Operating Pressure: 10 Bar
Pressure Equivalent: 145 PSI
Pressure Equivalent: 1 MPa
Rated Air Flow: 600 CFM
Rated Air Flow: 16.99 m³/min
PRESSURE-WISE AIRFLOW REFERENCE
The official SJ specification sheet lists the following airflow values for the SJ RV150 at different pressure configurations:
• 8 Bar: 717 CFM / 20.31 m³/min
• 10 Bar: 600 CFM / 16.99 m³/min
• 13 Bar: 516 CFM / 14.61 m³/min
IMPORTANT SPECIFICATION NOTE
For the SJ RV150 10 bar product configuration, the applicable rated airflow is 600 CFM (16.99 m³/min).
The 8 bar and 13 bar airflow figures represent different pressure configurations and must not be interchanged with the 10 bar rating.
INDUSTRIAL APPLICATIONS
The SJ RV150 150 HP VFD screw air compressor can be evaluated for large manufacturing facilities, process industries and industrial installations requiring substantial compressed air capacity at 10 bar.
With a specified airflow of 600 CFM (16.99 m³/min), it is relevant to assessing centralized compressed air generation, multi-line manufacturing operations and industrial systems with significant pneumatic demand.
Its suitability for a particular application depends on actual airflow consumption, minimum operating pressure, air quality, operating hours and the number of machines operating simultaneously.
1. AUTOMOTIVE MANUFACTURING PLANTS
Automotive manufacturing facilities use compressed air across pneumatic assembly systems, robotic fixtures, automated handling equipment and selected production processes.
The SJ RV150 can be evaluated where the combined compressed air demand of the relevant production equipment requires a high-capacity supply.
2. CNC AND VMC MACHINING CLUSTERS
Large machining facilities may operate multiple CNC and VMC machines simultaneously.
Compressed air can be required for pneumatic clamping, tool-related functions, fixtures, purging and other machine-specific operations.
The SJ RV150 can be considered where the combined airflow consumption and pressure requirements of the machining cluster justify its capacity.
3. PACKAGING AND BOTTLING PLANTS
Large packaging and bottling operations can have substantial compressed air requirements across filling, sealing, labelling, conveying and pneumatic automation equipment.
The compressor can be evaluated where several production lines operate simultaneously and compressed air consumption changes according to production schedules.
4. INDUSTRIAL AUTOMATION AND ROBOTICS
Automated manufacturing systems use compressed air for pneumatic actuators, cylinders, gripping equipment, fixtures and material-handling operations.
The variable-speed arrangement can be relevant where compressed air consumption changes according to production cycles and the number of operating machines.
5. TEXTILE MANUFACTURING
Textile facilities may use compressed air for selected pneumatic controls, machine operations, automation equipment and auxiliary processes.
Actual compressor capacity requirements depend on the machinery, production process, number of operating machines and simultaneous air consumption.
6. PLASTIC PROCESSING AND INJECTION MOULDING
Plastic processing plants can require compressed air for pneumatic automation, material handling, machine controls and auxiliary equipment.
The SJ RV150 can be evaluated for larger facilities where the combined demand of these operations requires substantial compressed air capacity.
7. POWDER COATING AND INDUSTRIAL PAINTING
Industrial coating operations use compressed air for spray equipment and related pneumatic functions.
Air treatment is particularly important because moisture and oil contamination can affect coating quality. Dryer and filtration equipment should be selected according to the required finishing quality.
8. ENGINEERING AND FABRICATION INDUSTRIES
Large engineering and fabrication facilities may use compressed air for pneumatic tools, assembly systems, fixtures, material handling and production equipment.
The SJ RV150 can be considered where the combined demand of these operations justifies its rated capacity.
9. ELECTRONICS AND PRECISION MANUFACTURING
Selected electronics and precision manufacturing processes use compressed air for pneumatic equipment, automation and controlled cleaning applications.
Filtration and moisture specifications must be determined according to the actual process requirements. General utility compressed air should not automatically be considered suitable for sensitive or product-contact applications.
10. CHEMICAL AND PROCESS INDUSTRIES
Process facilities may require compressed air for pneumatic control systems, actuators, material handling and selected production equipment.
The SJ RV150 can be evaluated where the required airflow and pressure fall within its specified operating capability.
Instrument air and critical process air require appropriate air treatment and quality verification. Applications involving hazardous or corrosive environments also require suitable equipment and installation assessment.
11. CENTRALIZED FACTORY COMPRESSED AIR SYSTEMS
The SJ RV150 can be evaluated for centralized compressed air generation supplying several production departments through a common distribution network.
A centralized installation should account for:
• Total connected equipment demand.
• Simultaneous operating demand.
• Average and peak airflow requirements.
• Air receiver capacity.
• Pipeline diameter and pressure losses.
• Required pressure at the most distant point of use.
• Air leakage and unnecessary consumption.
• Future production expansion.
• Required compressed air quality.
The compressor should be selected according to measured or calculated plant demand, not simply the number of machines or factory size.
12. LARGE MULTI-LINE PRODUCTION FACILITIES
Factories operating several production lines may experience changing compressed air consumption as individual lines start, stop or change production rates.
The SJ RV150's VFD arrangement can be evaluated for such installations where demand variation falls within the compressor's designed operating range.
COMPATIBLE ACCESSORIES
The SJ RV150 can be integrated with suitable compressed air storage, treatment and distribution equipment to develop a complete industrial compressed air system.
Compatible accessories include:
• Air Receiver Tank – Stores compressed air and helps stabilise system pressure.
• Refrigerated Air Dryer – Removes moisture for general-purpose industrial compressed air.
• Desiccant Air Dryer – Provides lower pressure dew point air where required.
• Moisture Separator – Removes bulk liquid moisture from compressed air.
• Pre-Filter – Removes larger particles and liquid contaminants.
• After-Filter – Provides additional downstream filtration.
• Micro Filter – Supports finer aerosol filtration requirements.
• Activated Carbon Filter – Helps reduce oil vapour and odour.
• Automatic Drain Valve – Automatically removes accumulated condensate.
• Aluminium Air Piping – Distributes compressed air throughout the factory.
• Oil-Water Separator – Treats oil-contaminated condensate before disposal.
• Airflow Meter – Measures compressed air consumption.
• Dew Point Monitor – Monitors moisture performance of treated compressed air.
For a 600 CFM compressor installation, accessory capacity should be selected according to actual airflow and operating pressure, including appropriate consideration of pressure drop and operating conditions.
FREQUENTLY ASKED QUESTIONS
Q1. What is the motor capacity of the SJ RV150 screw air compressor?
The SJ RV150 is a 150 HP industrial rotary screw air compressor with a motor power rating of 110 kW.
Q2. What is the airflow capacity of the SJ RV150 at 10 bar?
The specified airflow capacity is 600 CFM, equivalent to 16.99 m³/min, at 10 bar operating pressure.
Q3. Is the SJ RV150 a fixed-speed or variable-speed compressor?
The SJ RV150 belongs to Sarv Jagat's variable-speed rotary screw compressor range. It uses VFD technology to regulate motor speed according to compressed air demand within its designed operating range.
Q4. How does VFD technology work in a 150 HP screw compressor?
The VFD changes the electrical frequency supplied to the motor, allowing motor speed to increase or decrease according to the control system's demand signal. This helps adjust compressor output to changing compressed air consumption within the permitted operating range.
Q5. Can a 150 HP VFD compressor reduce electricity consumption?
It can reduce electricity consumption during suitable partial-load operating conditions by reducing motor speed when compressed air demand decreases.
Actual savings depend on the plant demand profile, operating pressure, leakage, control settings, operating hours and compressor operating limits. A fixed percentage of savings cannot be guaranteed without a site-specific energy assessment.
Q6. Which industries can use the SJ RV150 10 bar compressor?
It can be evaluated for automotive manufacturing, CNC and VMC machining, packaging and bottling, industrial automation, textile manufacturing, plastic processing, engineering and fabrication, chemical and process industries and centralized factory compressed air systems.
Q7. Can the SJ RV150 supply multiple production departments?
It can be considered for a centralized compressed air system supplying multiple departments if their combined airflow demand and pressure requirements remain within the compressor's capability.
Receiver sizing, pipeline pressure losses, peak demand and required air quality must also be assessed.
Q8. Can the SJ RV150 be connected to an air dryer and receiver tank?
Yes. It can be integrated with a suitably sized air receiver tank, refrigerated or desiccant air dryer, moisture separator and filtration equipment.
These accessories are optional unless included in the approved quotation and should be selected according to the actual system operating requirements.
Q9. Is 10 bar pressure suitable for every industrial application?
No. Required pressure depends on the machinery and process.
Selecting a higher pressure than necessary can increase electricity consumption. The minimum pressure requirement at the point of use and distribution-system pressure losses should be evaluated before selecting the 10 bar configuration.
Q10. What maintenance is required for the SJ RV150?
Maintenance generally includes inspection and servicing of the air intake filter, lubricating oil, oil filter, air-oil separator, cooling system, electrical connections and VFD-related components according to the manufacturer's maintenance schedule.
Actual service intervals should follow the approved service documentation.
Q11. Is the SJ RV150 suitable for food and pharmaceutical applications?
It may be considered for general utility compressed air, depending on the application.
Direct product-contact and critical process applications require a defined compressed air quality specification, suitable downstream treatment and process validation. The compressor alone does not guarantee product-contact air quality.
Q12. How should I select an air dryer for the SJ RV150?
The dryer should be selected according to the actual airflow of 600 CFM at the specified operating pressure, along with inlet temperature, ambient conditions, required pressure dew point and permissible pressure drop.
A dryer should not be selected solely on the basis of the compressor's 150 HP motor rating.
WHY CHOOSE SARV JAGAT?
Sarv Jagat Corporation provides industrial compressed air solutions for manufacturing facilities, process industries, engineering companies and other applications that depend on compressed air generation.
The SJ RV150 is part of Sarv Jagat's variable-speed rotary screw compressor range, intended for industrial users evaluating a 150 HP compressor with a specified airflow of 600 CFM at 10 bar.
REASONS TO CONSIDER SARV JAGAT
• Industrial Screw Compressor Range: Multiple motor capacities, pressure ratings and airflow configurations for different industrial requirements.
• Variable-Speed Technology: VFD compressor options for applications with changing compressed air demand.
• Technical Selection Support: Assistance in evaluating compressor capacity, operating pressure and VFD suitability.
• Complete Compressed Air Solutions: Integration options for air receivers, dryers, filters and compressed air piping.
• Spare Parts Support: Assistance with compatible compressor maintenance components, subject to model and configuration.
• Service Support: Compressor maintenance and troubleshooting support.
• Industrial Application Knowledge: Equipment selection support for manufacturing and process environments.
• Ahmedabad-Based Business: Sarv Jagat Corporation operates from Ahmedabad, Gujarat, India.
For SJ RV150 pricing, technical details, VFD configuration, installation requirements and a customised compressed air system quotation, contact Sarv Jagat Corporation.
SARV JAGAT – INDUSTRIAL SCREW AIR COMPRESSORS, COMPRESSED AIR SOLUTIONS, SPARES & SERVICE.
Complementary Equipment
View All 84 ModelsRelated Industrial Screw Compressors
SJ RF 10Fixed

⚙️ Fixed Speed Drive
10 HP 8 Bar SJ Fixed Speed Screw Air Compressor
Buy 10 HP 8 Bar Fixed Speed Screw Air Compressor from Sarv Jagat. Delivers 45 CFM with reliable rotary screw technology, energy efficient & Low maintenance.
Power10 HP7.5 kW
Pressure8 Bar116 PSI
Air Delivery45 CFM1.27 m³/m
SJ RF 20Fixed

⚙️ Fixed Speed Drive
20 HP 8 Bar SJ Fixed Speed Screw Air Compressor
Buy SJ RF20 20 HP 8 Bar Fixed Speed Screw Air Compressor. 85 CFM (2.41 m³/min), oil injected rotary screw technology for industrial use.
Power20 HP15 kW
Pressure8 Bar115 PSI
Air Delivery85 CFM2.41 m³/m

